The Riken Keiki GD-A80 is a Combustible Detector Head which is ideal for measuring flammable gases.
It is designed to be linked to the RM-5000 Multi-Channel Gas Monitoring Panel or the RM-6000 Single Channel Gas Monitoring Panel in fixed systems.
The GD-A80 can measure a variety of Combustible gases such as Methane, Iso-Butane, Propane and even Hydrogen.
The GD-A80N - Thermal conductivity sensor to allow measurement of Combustible gases such as Hydrogen, in an Inert atmosphere in the % Vol range with 0-5% , 0-10% and 0-100% vol range options available.
For RP-D58 Explosion proof ATEX pump unit Click here
Ideal suited for a wide variety of applications.
The ability to measure combustible gases in an inert environment in % volume range.
Trouble free operation.
Suitable for hazardous areas & Hydrogen.
Flexibility for any application.
Flexibility for any application.
Can be used with an external pump.
The GD-A80 is explosion proof and complies to ATEX Regulations under Directives.
It has a wide operating range of -20 Degrees to + 53 Degrees Centigrade, applications for GD-A80 are wide ranging and include Marine Shipping Systems, Manufacturing, Industrial Kitchens, Industrial Boiler and Plant Rooms, and other combustible gas detection applications.
The GD-A80 is ideal for measuring Hydrogen in Laboratories and can be highly mounted in the room. The GD-A80 sensor has a long life and should give many years of dependable service.
The gas detection units are easy to service as well as maintain.
The GD-A80 is ideal for attaching to the Single Channel RM-6000 monitor unit.
The Riken Keiki RM-6000 is a Single Channel Gas Monitor Panel, the RM-6000 is ideal for monitoring combustible gases, oxygen, and toxic gases. It is ideal for a range of industrial sectors, Manufacturing, in addition to Marine applications.
Users can connect detector heads for Carbon Monoxide, Oxygen, combustible gases, and other toxic gases.
Detector heads that can be used include the SD-1 and also the GD-A80 , GD-F3-AA as well as the GD-70D Intelligent pumped gas monitors.
The indicator units each have an independent digital display that is easy to read, each indicator has a bar meter and multi-colour display for ease of monitoring. The RM-6000 is compatible with previous generation Riken Single Channel Monitor Panels.
Power consumption is extremely low.
Model | GD-A80 |
Detection Principle | Catalytic combustion / New Ceramic type |
Gas to be Detected | Combustible Gases |
Detection Range | Diffusion Type |
Transmission cable | CVV 1.25mm2 or 2mm” 4-core |
Transmission distance | Depends on Indicator |
Power Supply | Supply from Indicator |
Operating Temperature | -20 – +53C in constant condition |
Operating humidity | Below 95% RH ( non-condensing ) |
Structure | Wall Mounting type |
External Dimensions / Weight | Approx 78 (W) x 154 (H) x 105 (D) mm Approx 1.0Kg |
Explosion Proof | Flame Proof Enclosures ( ATEX 11 1G Ex d 11C T4 Gb
IECEx : Ex d 11C T4 Gb |
Ingress Rating | IP65 |
We are able to provide products and advice usually within short timescales. For product advice, servicing and enquiries, please contact our experienced team: